Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Diagnostic accuracy of stereotactic large‐core needle biopsy for nonpalpable breast disease: Results of a multicenter prospective study with 95% surgical confirmation
178
Zitationen
1
Autoren
2002
Jahr
Abstract
Stereotactic large-core needle biopsy is increasingly applied for the diagnosis of nonpalpable breast disease. Our study examines whether this minimally invasive technique is sufficiently accurate to replace surgical breast biopsy. In a prospective multicenter study, 973 consecutive women with 1,029 nonpalpable breast lesions were offered stereotactic 14-gauge needle biopsy. If the needle biopsy yielded breast cancer, the patient was offered therapeutic surgery. Surgical biopsy was proposed in cases of needle biopsies without malignancy. An expert panel reviewed all discrepancies in histologic diagnosis between the needle biopsy and open biopsy. Forty-five patients withdrew from participation and 113 (11%) planned needle biopsy procedures were cancelled. Of the 871 successful biopsy procedures, 95% were confirmed surgically. In 13 cases (1.5%), insufficient material was obtained for histologic assessment. Fifty-five percent of the needle biopsies were diagnosed as malignant (290 invasive cancers, 190 ductal carcinoma in situ). Thirteen of the 322 lesions (4%, 95% CI 2-7%) with a benign needle biopsy diagnosis contained malignancy after surgery. Six of the 26 (23%, 95% CI 9-44%) lesions with a high-risk diagnosis (atypical ductal or lobular hyperplasia or lobular carcinoma in situ) were diagnosed as malignant after surgery. Five of the 30 lesions containing normal breast tissue held malignancy (17%, 95% CI 6-35%). Guidelines for the management of different categories of needle biopsy diagnoses were made. Application of these guidelines to the present findings resulted in sensitivity and specificity rates of 97% (95% CI 95-98%) and 99% (95% CI 97-100%), respectively. Stereotactic large-core needle biopsy is an accurate diagnostic instrument for nonpalpable breast disease. It may safely replace needle localised open-breast biopsy provided that high-risk and normal breast tissue diagnoses are followed by needle or open-breast biopsy.
Ähnliche Arbeiten
Twenty-Year Follow-up of a Randomized Trial Comparing Total Mastectomy, Lumpectomy, and Lumpectomy plus Irradiation for the Treatment of Invasive Breast Cancer
2002 · 6.182 Zit.
pathological prognostic factors in breast cancer. I. The value of histological grade in breast cancer: experience from a large study with long‐term follow‐up
1991 · 6.170 Zit.
Effects of radiotherapy and of differences in the extent of surgery for early breast cancer on local recurrence and 15-year survival: an overview of the randomised trials
2005 · 5.112 Zit.
Twenty-Year Follow-up of a Randomized Study Comparing Breast-Conserving Surgery with Radical Mastectomy for Early Breast Cancer
2002 · 4.414 Zit.
Ki67 expression in breast cancer
2016 · 4.396 Zit.