Abstract
A method based on repeated whole-body imaging in combination with blood and urinary activity data over time was developed to determine the absorbed dose to the bone marrow. The dose-limiting organ was the kidney in 197 of 200 patients. In 50% of the patients, more than 4 cycles of 7.4 GBq of (177)Lu-octreotate could be administered, whereas 20% of the subjects were treated with fewer than 4 cycles. Individualized absorbed dose calculation is essential to optimize the therapy.