Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Befundung von digitalen Intensiv- bzw. Bettlungenaufnahmen am Monitor vs. Hardcopy: eine klinische ROC-Studie
6
Zitationen
6
Autoren
1994
Jahr
Abstract
45 bedside chest examinations acquired with storage phosphorus radiography, were displayed on a viewing box as single-format hard copies and at a high-performance digital reporting console. 6 observers performed an ROC study. For the pathologies under question, significantly better results were shown in monitor reporting due to pneumonic infiltration whereas no significant differences were found for pulmonary or mediastinal masses, or for pneumothoraces.