Reproducibility and Accuracy of Quantitative Myocardial Blood Flow Assessment with <sup>82</sup>Rb PET: Comparison with <sup>13</sup>N-Ammonia PET
261
Zitationen
10
Autoren
2009
Jahr
Abstract
MBF quantitation with GFADS and dynamic (82)Rb PET demonstrated excellent reproducibility as well as intra- and interobserver reliability. The accuracy of the absolute quantitation of MBF with factor and compartment analyses and dynamic (82)Rb PET was very good, compared with that achieved with (13)N-ammonia, for MBF of up to 2.5 mL/g/min.