Abstract
Turnaround time is an important quality indicator in surgical pathology. Retrospective analysis of three data points in September 2014, January 2015, and February 2015 showed that on average, about a quarter (24%) of routine surgical pathology cases (26%, 19%, and 27% respectively) are not reported on time and do not meet the accepted level of the College of American Pathologists' (CAP) standard turnaround time, which states at least 90% of routine surgical pathology cases should be reported and verified within two days. Our daily observation supported by a root cause analysis exercise revealed that subprocesses including slide allocation and delivery to pathologists, slide review by pathologists, report editing by transcriptionists, and report verification by pathologists are where most delays occur. Thus, to tackle these process issues we developed a quality improvement project using the model of improvement methods to streamline the sample flow process and avoid unjustified reporting delay. The improvement ideas included developing a time log sheet to be attached with all pathology requests, and sending a daily reminder email followed by a phonecall to all pathologists to verify completed reports on the same day. These intervention elements were tested using multiple PDSA cycles resulting in a very noticeable improvement, with more than 94% of all routine cases reported in less than two days, meeting and exceeding the CAP standards. Such noticeable improvement in turnaround of surgical pathology reports will eventually lead to improving the quality and safety of patient care outcome, including diagnosing patients on time, developing the appropriate treatment plan, and avoiding unjustified complications resulting in morbidity and mortality due to delayed reports.
Ähnliche Arbeiten
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
1986 · 47.380 Zit.
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
1982 · 21.647 Zit.
Basic principles of ROC analysis
1978 · 6.051 Zit.
Methods for the determination of limit of detection and limit of quantitation of the analytical methods
2011 · 3.110 Zit.
All About Albumin: Biochemistry, Genetics, and Medical Applications
1995 · 3.103 Zit.