Second-Generation Dual-Energy Computed Tomography of the Abdomen
27
Zitationen
12
Autoren
2013
Jahr
Abstract
PURPOSE: This study was designed to compare the radiation dose in abdominal dual-energy (DE) and single-energy (SE) acquisitions obtained in clinical practice with a second-generation DE computed tomography (DECT) and to analyze the dose variation in comparison with an SE acquisition performed with a 64-row SECT (SECT). METHODS: A total of 130 patients divided into 2 groups underwent precontrast and portal abdominal 128-row CT examination. In group A, DE portal acquisition was performed using a detector configuration of 2 × 40 × 0.6 mm, tube A at 80 kVp and a reference value of 559 mAs, tube B at 140 kVp and a reference value of 216 mAs, pitch 0.6, and online dose modulation; group B underwent SE portal acquisition using a detector configuration of 64 × 0.6 mm, 120 kVp and a reference value of 180 mAs, pitch 0.75, and online dose modulation. Group C consisted of 32 subjects from group A previously studied with 64-row SECT using the following parameters: detector configuration 64 × 0.6 mm, 120 kVp and a reference value of 180 mAs, pitch 0.75, and online dose modulation. In each group, the portal phase dose-length product and radiation dose (mSv) were calculated and normalized for a typical abdominal acquisition of 40 cm. RESULTS: After normalization to standard 40-cm acquisition, a dose-length product of 599.0 ± 133.5 mGy · cm (range, 367.5 ± 1231.2 mGy · cm) in group A, 525.9 ± 139.2 mGy · cm (range, 215.7-882.8 mGy · cm) in group B, and 515.9 ± 111.3 mGy · cm (range, 305.5-687.2 mGy · cm) in group C was calculated for portal phase acquisition.A significant radiation dose increase (P < 0.05) was observed in group A (10.2 ± 2.3 mSv) compared with group B (8.9 ± 2.4) and group C (8.8 ± 1.9 mSv). No significant difference (P > 0.05) was reported between SE 64- and 128-row acquisitions. A significant positive correlation between radiation dose and body mass index was observed in each group (group A, r = 0.59, P < 0.0001; group B, r = 0.35, P < 0.0001; group C, r = 0.20, P = 0.0098). CONCLUSIONS: In clinical practice, abdominal DECT acquisition shows a significant but minimal radiation dose increase, on the order of 1 mSv, compared with 64- and 128-row SE acquisition. The slightly increased radiation dose can be justified if the additional information obtained using a spectral imaging approach directly impacts on patient management or reduce the overall radiation dose with the generation of virtual unenhanced images, which can replace the precontrast acquisition.
Ähnliche Arbeiten
<i>ATHENA</i>,<i>ARTEMIS</i>,<i>HEPHAESTUS</i>: data analysis for X-ray absorption spectroscopy using<i>IFEFFIT</i>
2005 · 16.211 Zit.
Computed Tomography — An Increasing Source of Radiation Exposure
2007 · 8.640 Zit.
Quantification of coronary artery calcium using ultrafast computed tomography
1990 · 7.673 Zit.
Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the Heart
2002 · 6.931 Zit.
Computational Radiomics System to Decode the Radiographic Phenotype
2017 · 6.346 Zit.