Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Automatic method for computing radiographic parameters of radial metaphyseal fractures in radiographs for surgical decision support
0
Zitationen
4
Autoren
2022
Jahr
Abstract
Purpose Distal radius fractures (DRF) are common types of fractures with a high incident rate. DRF can be treated either by cast or surgery. To determine the clinical procedure and the operative management, standardized guidelines have become increasingly common. As operative indications are controversial, radiographic parameters (RPs) can provide objective support for effective decision making. Calculating the RPs manually from radiographs is time consuming and subject to observer variability and clinician experience. Our aim was to develop an automatic method for accurately and reliably computing 10 RPs associated with DRF in anteroposterior (AP) and lateral radiographs of a fractured hand with and without cast. Methods The inputs are the AP and lateral radiographs of the fractured hand with or without cast. The outputs are 10 RP values and composite images showing the landmark points and axes used in the RPs computation on the radiographs. Our method comprises three main steps: 1) segmentation of the radius and the ulna with a deep learning radiograph pixel classifier; 2) landmark points and axis extraction from the segmentations using geometric model-based methods; 3) RPs computation from the landmarks and generation of composite images. Our study tested the accuracy of step 2. The dataset consists of 20 pairs of AP and lateral radiographs. Ground truth radius and ulna segmentations were manually performed by an expert clinician co-author. Ground truth landmarks were manually located and annotated by the two expert clinician co-authors. The computed RP was considered accurate (in range) when its value was inside the inter and intra observer variability range of the manual annotation. The overall accuracy of the AP and lateral measurements was obtained by averaging the accuracy of each RP. Results The accuracy of the computed AP RPs is 92.7%. The Radial Length and Radial Shift are within the observer variability range; for the Radial Angle, Ulnar Variance and Step all cases are within range except for one outlier; the Gap has two outlier cases. The accuracy of the computed lateral RPs is 100%: all four Palmer Tilt, Dorsal Shift, Gap, and Step are within the clinician observer variability. Conclusion Automatic computation of distal radius fractures RPs from AP and lateral radiographs of hands with and without cast can be performed accurately. Precise and consistent measurement of RPs may improve the clinical decision making process.
Ähnliche Arbeiten
RADIOGRAPHIC ATLAS OF SKELETAL DEVELOPMENT OF THE HAND AND WRIST
1959 · 5.546 Zit.
Development of an upper extremity outcome measure: The DASH (disabilities of the arm, shoulder, and head)
1996 · 4.955 Zit.
Rating Systems in the Evaluation of Knee Ligament Injuries
1985 · 4.551 Zit.
ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion—Part II: shoulder, elbow, wrist and hand
2004 · 4.433 Zit.
Isolated Hand Paresis: A Case Series
2013 · 4.077 Zit.