Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Feasibility of remote monitoring for fatal coronary heart disease using Apple Watch ECGs
8
Zitationen
16
Autoren
2024
Jahr
Abstract
Background: Fatal coronary heart disease (FCHD) is often described as sudden cardiac death (affects >4 million people/year), where coronary artery disease is the only identified condition. Electrocardiographic artificial intelligence (ECG-AI) models for FCHD risk prediction using ECG data from wearable devices could enable wider screening/monitoring efforts. Objectives: To develop a single-lead ECG-based deep learning model for FCHD risk prediction and assess concordance between clinical and Apple Watch ECGs. Methods: An FCHD single-lead ("lead I" from 12-lead ECGs) ECG-AI model was developed using 167,662 ECGs (50,132 patients) from the University of Tennessee Health Sciences Center. Eighty percent of the data (5-fold cross-validation) was used for training and 20% as a holdout. Cox proportional hazards (CPH) models incorporating ECG-AI predictions with age, sex, and race were also developed. The models were tested on paired clinical single-lead and Apple Watch ECGs from 243 St. Jude Lifetime Cohort Study participants. The correlation and concordance of the predictions were assessed using Pearson correlation (R), Spearman correlation (ρ), and Cohen's kappa. Results: The ECG-AI and CPH models resulted in AUC = 0.76 and 0.79, respectively, on the 20% holdout and AUC = 0.85 and 0.87 on the Atrium Health Wake Forest Baptist external validation data. There was moderate-strong positive correlation between predictions (R = 0.74, ρ = 0.67, and κ = 0.58) when tested on the 243 paired ECGs. The clinical (lead I) and Apple Watch predictions led to the same low/high-risk FCHD classification for 99% of the participants. CPH prediction correlation resulted in an R = 0.81, ρ = 0.76, and κ = 0.78. Conclusion: Risk of FCHD can be predicted from single-lead ECGs obtained from wearable devices and are statistically concordant with lead I of a 12-lead ECG.
Ähnliche Arbeiten
A Real-Time QRS Detection Algorithm
1985 · 7.681 Zit.
An Overview of Heart Rate Variability Metrics and Norms
2017 · 6.639 Zit.
Power Spectrum Analysis of Heart Rate Fluctuation: A Quantitative Probe of Beat-to-Beat Cardiovascular Control
1981 · 5.075 Zit.
The impact of the MIT-BIH Arrhythmia Database
2001 · 4.578 Zit.
Decreased heart rate variability and its association with increased mortality after acute myocardial infarction
1987 · 4.001 Zit.