Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Development and Validation of a Literature Screening Tool: Few-Shot Learning Approach in Systematic Reviews
0
Zitationen
8
Autoren
2024
Jahr
Abstract
BACKGROUND: Systematic reviews (SRs) are considered the highest level of evidence, but their rigorous literature screening process can be time-consuming and resource-intensive. This is particularly challenging given the rapid pace of medical advancements, which can quickly make SRs outdated. Few-shot learning (FSL), a machine learning approach that learns effectively from limited data, offers a potential solution to streamline this process. Sentence-bidirectional encoder representations from transformers (S-BERT) are particularly promising for identifying relevant studies with fewer examples. OBJECTIVE: This study aimed to develop a model framework using FSL to efficiently screen and select relevant studies for inclusion in SRs, aiming to reduce workload while maintaining high recall rates. METHODS: We developed and validated the FSL model framework using 9 previously published SR projects (2016-2018). The framework used S-BERT with titles and abstracts as input data. Key evaluation metrics, including workload reduction, cosine similarity score, and the number needed to screen at 100% recall, were estimated to determine the optimal number of eligible studies for model training. A prospective evaluation phase involving 4 ongoing SRs was then conducted. Study selection by FSL and a secondary reviewer were compared with the principal reviewer (considered the gold standard) to estimate the false negative rate. RESULTS: Model development suggested an optimal range of 4-12 eligible studies for FSL training. Using 4-6 eligible studies during model development resulted in similarity thresholds for 100% recall, ranging from 0.432 to 0.636, corresponding to a workload reduction of 51.11% (95% CI 46.36-55.86) to 97.67% (95% CI 96.76-98.58). The prospective evaluation of 4 SRs aimed for a 50% workload reduction, yielding numbers needed to screen 497 to 1035 out of 995 to 2070 studies. The false negative rate ranged from 1.87% to 12.20% for the FSL model and from 5% to 56.48% for the second reviewer compared with the principal reviewer. CONCLUSIONS: Our FSL framework demonstrates the potential for reducing workload in SR screening by over 50%. However, the model did not achieve 100% recall at this threshold, highlighting the potential for omitting eligible studies. Future work should focus on developing a web application to implement the FSL framework, making it accessible to researchers.
Ähnliche Arbeiten
The PRISMA 2020 statement: an updated guideline for reporting systematic reviews
2021 · 89.438 Zit.
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement
2009 · 83.031 Zit.
The Measurement of Observer Agreement for Categorical Data
1977 · 77.783 Zit.
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
2009 · 63.404 Zit.
Measuring inconsistency in meta-analyses
2003 · 62.064 Zit.