Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Abstract 4368127: Multi-Center Validation of an AI-Enhanced ECG Model for Predicting Echocardiographic Abnormalities: A Large-Scale Study Across 14 Tertiary Care Centers
0
Zitationen
8
Autoren
2025
Jahr
Abstract
Background: While numerous AI models leverage ECGs to predict specific cardiac abnormalities, few have been validated at scale across diverse populations and echocardiographic pathologies. This study evaluates the external performance of a deep learning ensemble that predicts a composite of major echocardiographic abnormalities —including reduced ejection fraction (≤35%), valvular disease (mild to severe stenosis and/or moderate to severe regurgitation of Mitral, Aortic and/or Tricuspid valves), and elevated pulmonary artery pressure—from standard 12-lead ECG images. Methods: We retrospectively analyzed 44,403 ECGs from 43,346 patients (≥15 years) across 14 centers between July and September 2024. The data was split into two cohorts: Co1 included 28,509 ECGs paired with same-day echocardiograms; Co2 included 15,894 ECGs (from 15,401 patients) without same-day echocardiograms. The ensemble model—comprising two InceptionNetV3 and one ResNet50 networks trained on DICOM ECG images—classified ECGs as positive or negative for any one of eight echocardiographic dysfunctions based on the Youden index threshold (0.27) calculated during model development. Results: On Co1, the model achieved an ROCAUC of 84% , PR-AUC of 45% , sensitivity 74% , specificity 79% , PPV 34% , NPV 96% , and overall accuracy of 80% . A robust performance was observed in all subsets (Fig. 1). In the subset of false positives (5,127 patients), 932 patients who had follow-up echocardiograms within a median of 54 days revealed that 28% eventually showed echocardiographic dysfunction. In Co2, out of the 15,401 patients, 2,185 patients underwent at least one echocardiogram within 6 months post-ECG. Among those, of the 830 patients who were previously flagged positive for dysfunction by the model, 49% were found to have dysfunction, with a median interval of 28 days between the initial ECG and echo. Conclusion: This AI-enhanced ECG model demonstrates strong generalizability and clinical utility for early identification of echocardiographic abnormalities, offering a scalable solution to triage echocardiography referrals across varied clinical settings, requiring about 2.9 echos to confirm 1 case flagged as dysfunction by the model. Prospective validation is underway to further evaluate its impact on diagnostic workflows and patient outcomes.
Ähnliche Arbeiten
A Real-Time QRS Detection Algorithm
1985 · 7.634 Zit.
An Overview of Heart Rate Variability Metrics and Norms
2017 · 6.434 Zit.
Power Spectrum Analysis of Heart Rate Fluctuation: A Quantitative Probe of Beat-to-Beat Cardiovascular Control
1981 · 5.060 Zit.
The impact of the MIT-BIH Arrhythmia Database
2001 · 4.513 Zit.
Decreased heart rate variability and its association with increased mortality after acute myocardial infarction
1987 · 3.990 Zit.