Assessment of clinical occupational dose reduction effect of a new interventional cardiology shield for radial access combined with a scatter reducing drape
30
Zitationen
9
Autoren
2015
Jahr
Abstract
OBJECTIVES: To assess the occupational dose reduction effect of a new interventional cardiology shield for radial access combined with a scatter reducing drape. BACKGROUND: Transradial access for catheterization has been shown to increase occupational radiation dose. Current shielding techniques are primarily based on the femoral access. This article looks at the clinical occupational combined dose reduction effect of a commercially available shield and drape which is specific to access type. METHODS: The evaluation took place in a busy interventional cardiology laboratory, with a single plane 30×40 cm flat panel detector (Siemens Artis Zee, Germany). Radiation exposure to staff was measured using electronic personal dosimeters (Unfors RaysafeAB, Sweden) placed at the collar. Patient radiation exposure was assessed using screening time and dose area product per case. Both staff and patient radiation exposure were monitored for a number of case types and operators before, during, and after deployment of the new shield and drapes. RESULTS: The cardiologists' overall median collar badge reading per case reduced from 15.4 μSv per case without the shield/drape combination to 7.3 μSv per case with the shield drape combination in situ (P<0.001). The radiographers badge reading was reduced from 4.2 μSv per case without to 2.5 μSv per case with the shield drape combination in situ (P<0.001). There was no statistical difference in the cardiac technician's badge reading. Patient's dose area product was not significantly affected by the placement of the shield and drape combination. CONCLUSIONS: The shield/drape combination can significantly reduce operator exposure in a cardiac catheterization laboratory.
Ähnliche Arbeiten
Computed Tomography — An Increasing Source of Radiation Exposure
2007 · 8.657 Zit.
Maximum Likelihood Reconstruction for Emission Tomography
1982 · 4.369 Zit.
The 2007 recommendations of the International Commission on Radiological Protection
2007 · 4.110 Zit.
Sources and effects of ionizing radiation
2018 · 3.989 Zit.
Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study
2012 · 3.628 Zit.