OpenAlex · Aktualisierung stündlich · Letzte Aktualisierung: 08.05.2026, 18:45

Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.

Radiation Dose Monitoring for Fluoroscopically Guided Interventional Procedures: Effect on Patient Radiation Exposure

2019·29 Zitationen·Radiology
Volltext beim Verlag öffnen

29

Zitationen

7

Autoren

2019

Jahr

Abstract

Purpose To analyze the clinical effect of continuous dose monitoring and patient follow-up for fluoroscopically guided vascular interventional procedures over 8 years. Materials and Methods In this retrospective study, an in-house semiautomated system was developed for fluoroscopic dose monitoring. The quarterly number of procedures from January 2010 to December 2017 was analyzed with count time series to estimate quarterly change rate. Technologists recorded four dose surrogates in custom fields of institutional dictation software through a Web interface. Radiation doses were transferred automatically to the radiology report and a centralized dose database when the radiologist initiated procedure dictation. A medical physicist reported weekly on procedures with air kerma at the reference point (K<sub>a,r</sub>) of 2 Gy or higher to a division-designated radiologist and hospital radiation safety committee who required the attending radiologist to set up follow-up appointments for patients who underwent procedures with a K<sub>a,r</sub> greater than or equal to 5 Gy. Results There were a total of 41 585 procedures; 1553 (3.7%) procedures had a K<sub>a,r</sub> of 2-5 Gy. Among 240 procedures with K<sub>a,r</sub> greater than 5 Gy, 22 had K<sub>a,r</sub> greater than 9 Gy. The percentage of high K<sub>a,r</sub> procedures decreased over time, going from 5.9% in 2010 to 2.0% in 2017 for procedures with K<sub>a,r</sub> of 2-5 Gy and from 1.0% in 2010 to 0.13% in 2017 for procedures with K<sub>a,r</sub> greater than or equal to 5 Gy. Relative reduction per quarter was approximately 2.7% (95% confidence interval: 1.5%, 3.8%) for K<sub>a,r</sub> of 2-5 Gy and 4.5% (95% confidence interval: 1.5%, 7.6%) for K<sub>a,r</sub> greater than or equal to 5 Gy. Conclusion Eight-year temporal trends show three- to eightfold reduction in the number of high-dose procedures. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Balter in this issue.

Ähnliche Arbeiten

Autoren

Institutionen

Themen

Radiation Dose and ImagingAdvanced X-ray and CT ImagingRadiology practices and education
Volltext beim Verlag öffnen