OpenAlex · Aktualisierung stündlich · Letzte Aktualisierung: 07.05.2026, 04:15

Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.

Real world evidence in cardiovascular medicine: ensuring data validity in electronic health record-based studies

2019·79 Zitationen·Journal of the American Medical Informatics AssociationOpen Access
Volltext beim Verlag öffnen

79

Zitationen

4

Autoren

2019

Jahr

Abstract

OBJECTIVE: With growing availability of digital health data and technology, health-related studies are increasingly augmented or implemented using real world data (RWD). Recent federal initiatives promote the use of RWD to make clinical assertions that influence regulatory decision-making. Our objective was to determine whether traditional real world evidence (RWE) techniques in cardiovascular medicine achieve accuracy sufficient for credible clinical assertions, also known as "regulatory-grade" RWE. DESIGN: Retrospective observational study using electronic health records (EHR), 2010-2016. METHODS: A predefined set of clinical concepts was extracted from EHR structured (EHR-S) and unstructured (EHR-U) data using traditional query techniques and artificial intelligence (AI) technologies, respectively. Performance was evaluated against manually annotated cohorts using standard metrics. Accuracy was compared to pre-defined criteria for regulatory-grade. Differences in accuracy were compared using Chi-square test. RESULTS: The dataset included 10 840 clinical notes. Individual concept occurrence ranged from 194 for coronary artery bypass graft to 4502 for diabetes mellitus. In EHR-S, average recall and precision were 51.7% and 98.3%, respectively and 95.5% and 95.3% in EHR-U, respectively. For each clinical concept, EHR-S accuracy was below regulatory-grade, while EHR-U met or exceeded criteria, with the exception of medications. CONCLUSIONS: Identifying an appropriate RWE approach is dependent on cohorts studied and accuracy required. In this study, recall varied greatly between EHR-S and EHR-U. Overall, EHR-S did not meet regulatory grade criteria, while EHR-U did. These results suggest that recall should be routinely measured in EHR-based studes intended for regulatory use. Furthermore, advanced data and technologies may be required to achieve regulatory grade results.

Ähnliche Arbeiten

Autoren

Institutionen

Themen

Electronic Health Records SystemsMachine Learning in HealthcareArtificial Intelligence in Healthcare and Education
Volltext beim Verlag öffnen