Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Improving Image Quality and Reducing Radiation Dose for Pediatric CT by Using Deep Learning Reconstruction
191
Zitationen
6
Autoren
2020
Jahr
Abstract
Background CT deep learning reconstruction (DLR) algorithms have been developed to remove image noise. How the DLR affects image quality and radiation dose reduction has yet to be fully investigated. Purpose To investigate a DLR algorithm's dose reduction and image quality improvement for pediatric CT. Materials and Methods DLR was compared with filtered back projection (FBP), statistical-based iterative reconstruction (SBIR), and model-based iterative reconstruction (MBIR) in a retrospective study by using data from CT examinations of pediatric patients (February to December 2018). A comparison of object detectability for 15 objects (diameter, 0.5-10 mm) at four contrast difference levels (50, 150, 250, and 350 HU) was performed by using a non-prewhitening-matched mathematical observer model with eye filter (<i>d'</i><sub><i>NPWE</i></sub>), task transfer function, and noise power spectrum analysis. Object detectability was assessed by using area under the curve analysis. Three pediatric radiologists performed an observer study to assess anatomic structures with low object-to-background signal and contrast to noise in the azygos vein, right hepatic vein, common bile duct, and superior mesenteric artery. Observers rated from 1 to 10 (worst to best) for edge definition, quantum noise level, and object conspicuity. Analysis of variance and Tukey honest significant difference post hoc tests were used to analyze differences between reconstruction algorithms. Results Images from 19 patients (mean age, 11 years ± 5 [standard deviation]; 10 female patients) were evaluated. Compared with FBP, SBIR, and MBIR, DLR demonstrated improved object detectability by 51% (16.5 of 10.9), 18% (16.5 of 13.9), and 11% (16.5 of 14.8), respectively. DLR reduced image noise without noise texture effects seen with MBIR. Radiologist ratings were 7 ± 1 (DLR), 6.2 ± 1 (MBIR), 6.2 ± 1 (SBIR), and 4.6 ± 1 (FBP); two-way analysis of variance showed a difference on the basis of reconstruction type (<i>P</i> < .001). Radiologists consistently preferred DLR images (intraclass correlation coefficient, 0.89; 95% CI: 0.83, 0.93). DLR demonstrated 52% (1 of 2.1) greater dose reduction than SBIR. Conclusion The DLR algorithm improved image quality and dose reduction without sacrificing noise texture and spatial resolution. © RSNA, 2020 <i>Online supplemental material is available for this article.</i>
Ähnliche Arbeiten
Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening
2011 · 10.844 Zit.
Computed Tomography — An Increasing Source of Radiation Exposure
2007 · 8.630 Zit.
Maximum Likelihood Reconstruction for Emission Tomography
1982 · 4.366 Zit.
The 2007 recommendations of the International Commission on Radiological Protection
2007 · 4.110 Zit.
Sources and effects of ionizing radiation
2018 · 3.988 Zit.