Digital radiography reject analysis of examinations with multiple rejects: an Australian emergency imaging department clinical audit
29
Zitationen
3
Autoren
2021
Jahr
Abstract
INTRODUCTION: The largest source of manmade ionising radiation exposure to the public stems from diagnostic medical imaging examinations. Reject analysis, a form of quality assurance, was introduced to minimise repeat exposures. The purpose of this study was to analyse projection-specific reject rates and radiographic examinations with multiple rejects. METHODS: A retrospective audit of rejected radiographs was undertaken in a busy Australian metropolitan emergency digital X-ray room from March to June 2018. The data were collected by reject analysis software embedded within the X-ray unit. Reject rates, and reasons for rejection for each X-ray projection were analysed. RESULTS: Data from 11, 596 images showed overall reject rate was 10.3% and the overall multiple reject rate was 1.3%. The projections with both a high number and high percentage of rejects were antero-posterior (AP) chest (175, 18.1%), AP pelvis (78, 22.5%), horizontal beam hip (61, 33.5%) and horizontal beam knee (116, 30.5%). The projections with both a high frequency and multiple reject rate were horizontal beam knee (32, 8.4%) and horizontal beam hip (17, 9.3%). The top reasons for multiple rejects were positioning (67.1%) and anatomy cut-off (8.4%). CONCLUSIONS: The findings of this study demonstrated that projection-specific reject and multiple reject analysis in digital radiography is necessary in identifying areas for quality improvement which will reduce radiation exposure to patients. Projections that were frequently repeated in this study were horizontal beam knee and horizontal beam hip. Future research could involve re-auditing the department following the implementation of improvement strategies to reduce unnecessary radiation exposure.
Ähnliche Arbeiten
Computed Tomography — An Increasing Source of Radiation Exposure
2007 · 8.657 Zit.
Maximum Likelihood Reconstruction for Emission Tomography
1982 · 4.369 Zit.
The 2007 recommendations of the International Commission on Radiological Protection
2007 · 4.110 Zit.
Sources and effects of ionizing radiation
2018 · 3.989 Zit.
Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study
2012 · 3.628 Zit.