Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Real-time x-ray abnormality alerts for emergency departments using a radiographer comment model - a multisite pilot study
10
Zitationen
12
Autoren
2023
Jahr
Abstract
INTRODUCTION: The timely communication of clinically significant image appearances to Emergency Department (ED) referrers is necessary for optimum patient care. Australian reliance on verbal communication only is time-limited, open to misinterpretation and lacks transparency. A combined radiographer alert and comment model was designed to reliably communicate image abnormalities to ED referrers in real-time. METHODS: A multidisciplinary steering group designed the model for all ED general imaging. Protocols were developed to document radiographer comments (critical, urgent and clinically significant) in patients' medical records. Critical findings were communicated directly to ED. Five NSW hospitals varying in size, complexity and population demographics piloted the model between three to twelve months during 2021-2022. Site auditors compared comments with the radiology report and designated each as True Positive (TP), False Positive (FP), indeterminate and clinically significant. Indeterminate cases were analysed by an external radiologist. Inter-observer consensus was obtained for all classifications via two independent auditors. The Positive Predictive Value (PPV), or precision of the comment, was calculated for each site. RESULTS: Radiographers (n = 69) provided comments for 1102 cases. The pooled average PPV for TP was 0.96; (0.947-0.971; 95% CI). The weighted mean error (FP comments) was 3.9%; (2.9% - 5.3%.; 95% CI). CONCLUSION: The Radiographer Comment model provided consistent levels of commenting precision and reproducibility across a range of sites with a pooled average PPV (0.96). The False Positive rate or weighted mean error (FP) of 3.9% (2.9% - 5.3%.; 95% CI) was low. IMPLICATIONS FOR FUTURE PRACTICE: A strategic, interprofessional approach in the implementation of an image alert combined with a Radiographer Comment can be adapted across a variety of hospital settings for ED and other departments.
Ähnliche Arbeiten
Refinement and reassessment of the SERVQUAL scale.
1991 · 3.967 Zit.
Radiobiology for the Radiologist.
1974 · 3.502 Zit.
ACR Thyroid Imaging, Reporting and Data System (TI-RADS): White Paper of the ACR TI-RADS Committee
2017 · 2.422 Zit.
Accuracy of Physician Self-assessment Compared With Observed Measures of Competence
2006 · 2.324 Zit.
Technology as an Occasion for Structuring: Evidence from Observations of CT Scanners and the Social Order of Radiology Departments
1986 · 2.247 Zit.
Autoren
Institutionen
- Monash Health(AU)
- Monash University(AU)
- Goulburn Base Hospital(AU)
- The University of Western Australia(AU)
- Princess Margaret Hospital for Children(AU)
- Perth Children's Hospital
- Sydney Adventist Hospital(AU)
- UNSW Sydney(AU)
- Innovative Clinical Research(US)
- South Western Sydney Local Health District(AU)
- Wollongong Hospital(AU)
- Far West Local Health District(AU)