Using AI to Improve Radiologist Performance in Detection of Abnormalities on Chest Radiographs
79
Zitationen
16
Autoren
2023
Jahr
Abstract
Background Chest radiography remains the most common radiologic examination, and interpretation of its results can be difficult. Purpose To explore the potential benefit of artificial intelligence (AI) assistance in the detection of thoracic abnormalities on chest radiographs by evaluating the performance of radiologists with different levels of expertise, with and without AI assistance. Materials and Methods Patients who underwent both chest radiography and thoracic CT within 72 hours between January 2010 and December 2020 in a French public hospital were screened retrospectively. Radiographs were randomly included until reaching 500 radiographs, with about 50% of radiographs having abnormal findings. A senior thoracic radiologist annotated the radiographs for five abnormalities (pneumothorax, pleural effusion, consolidation, mediastinal and hilar mass, lung nodule) based on the corresponding CT results (ground truth). A total of 12 readers (four thoracic radiologists, four general radiologists, four radiology residents) read half the radiographs without AI and half the radiographs with AI (ChestView; Gleamer). Changes in sensitivity and specificity were measured using paired <i>t</i> tests. Results The study included 500 patients (mean age, 54 years ± 19 [SD]; 261 female, 239 male), with 522 abnormalities visible on 241 radiographs. On average, for all readers, AI use resulted in an absolute increase in sensitivity of 26% (95% CI: 20, 32), 14% (95% CI: 11, 17), 12% (95% CI: 10, 14), 8.5% (95% CI: 6, 11), and 5.9% (95% CI: 4, 8) for pneumothorax, consolidation, nodule, pleural effusion, and mediastinal and hilar mass, respectively (<i>P</i> < .001). Specificity increased with AI assistance (3.9% [95% CI: 3.2, 4.6], 3.7% [95% CI: 3, 4.4], 2.9% [95% CI: 2.3, 3.5], and 2.1% [95% CI: 1.6, 2.6] for pleural effusion, mediastinal and hilar mass, consolidation, and nodule, respectively), except in the diagnosis of pneumothorax (-0.2%; 95% CI: -0.36, -0.04; <i>P</i> = .01). The mean reading time was 81 seconds without AI versus 56 seconds with AI (31% decrease, <i>P</i> < .001). Conclusion AI-assisted chest radiography interpretation resulted in absolute increases in sensitivity for all radiologists of various levels of expertise and reduced the reading times; specificity increased with AI, except in the diagnosis of pneumothorax. © RSNA, 2023 <i>Supplemental material is available for this article.</i>
Ähnliche Arbeiten
Refinement and reassessment of the SERVQUAL scale.
1991 · 3.967 Zit.
Features and uses of high-fidelity medical simulations that lead to effective learning: a BEME systematic review
2005 · 3.796 Zit.
Radiobiology for the Radiologist.
1974 · 3.502 Zit.
International evidence-based recommendations for point-of-care lung ultrasound
2012 · 2.828 Zit.
Radiation Dose Associated With Common Computed Tomography Examinations and the Associated Lifetime Attributable Risk of Cancer