Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Reliability of Gemini 2.5 Pro, ChatGPT 4.1, DeepSeek V3, and Claude Opus 4 in generating standardized CMR protocols
0
Zitationen
12
Autoren
2026
Jahr
Abstract
Artificial intelligence (AI) and large language models (LLMs) are increasingly integrated into radiology, offering new possibilities for advanced imaging techniques, including cardiovascular magnetic resonance (CMR). This proof-of-concept study assessed four high-performing LLMs (Gemini 2.5 Pro, ChatGPT 4.1, DeepSeek V3, and Claude Opus 4) on their ability to generate CMR protocols for 140 hypothetical cardiac cases. AI-generated protocols were compared against a reference standard established by a consensus between two experienced cardiovascular radiologists, following the Society for Cardiovascular Magnetic Resonance (SCMR) recommendations. Descriptive statistics were used to quantify the concordance of LLM-generated sequences with the SCMR guidelines. Statistical agreement was measured using Cohen and Fleiss κ statistics. Gemini 2.5 Pro achieved the highest concordance, aligning with the SCMR guidelines in 71.5% of all evaluated scenarios. Overall, LLMs showed moderate agreement with the SCMR protocols, with Gemini 2.5 Pro again performing best (Cohen κ = 0.55). Agreement was substantial for mandatory CMR sequences (Fleiss κ ∈ [0.69, 0.74]) and predominantly fair for optional sequences. The tested LLMs demonstrate a potential to generate efficient and pathology-adapted CMR protocols. Under expert supervision, this capability could streamline the imaging workflow and help extend CMR to primary healthcare centers through protocol automation. RELEVANCE STATEMENT: The potential of Gemini 2.5 Pro, ChatGPT 4.1, DeepSeek V3, and Claude Opus 4 to suggest pathology-adapted CMR protocols could improve imaging throughput and help to expand access to advanced cardiac diagnostics in primary healthcare centers. KEY POINTS: The tested large language models show potential for generating CMR protocols. Substantial agreement on mandatory CMR sequences promises more efficient examinations. Automation of CMR protocols could help to improve access to this advanced technique outside major medical institutions.
Ähnliche Arbeiten
Explainable Artificial Intelligence (XAI): Concepts, taxonomies, opportunities and challenges toward responsible AI
2019 · 8.200 Zit.
Stop explaining black box machine learning models for high stakes decisions and use interpretable models instead
2019 · 8.051 Zit.
High-performance medicine: the convergence of human and artificial intelligence
2018 · 7.416 Zit.
Proceedings of the 19th International Joint Conference on Artificial Intelligence
2005 · 5.776 Zit.
Peeking Inside the Black-Box: A Survey on Explainable Artificial Intelligence (XAI)
2018 · 5.410 Zit.
Autoren
Institutionen
- Clinical Emergency Hospital Bucharest(RO)
- Universitatea de Medicină, Farmacie, Științe și Tehnologie „George Emil Palade” din Târgu Mureș(RO)
- Ospedale Papa Giovanni XXIII(IT)
- Spitalul Clinic Judetean de Urgenta Târgu Mureş(RO)
- University of Milano-Bicocca(IT)
- Romanian University of Sciences and Arts "Gheorghe Cristea"(RO)
- Danylo Halytsky Lviv National Medical University(UA)
- Medical University of Lublin(PL)
- 1 Military Clinical Hospital with Outpatient Clinic(PL)
- Gdańsk Medical University(PL)