Dies ist eine Übersichtsseite mit Metadaten zu dieser wissenschaftlichen Arbeit. Der vollständige Artikel ist beim Verlag verfügbar.
Automated Shoulder Radiograph Quality Review to Support Efficient Workflow in the Emergency Department: The SQUIRE Deep Learning Ensemble
0
Zitationen
10
Autoren
2026
Jahr
Abstract
Suboptimal shoulder radiographs are a persistent challenge, leading to unnecessary radiation exposure, workflow delays, and increased costs from repeat imaging. Repeat imaging is most often required due to anatomy cutoff or suboptimal patient positioning, underscoring the need for targeted feedback and decision-support tools to improve image acquisition consistency. This study aimed to develop and validate an automated approach for assessing shoulder radiograph quality under realistic deployment conditions. We introduce new expert-verified quality annotations for 732 shoulder radiographs from the publicly available MURA dataset-representing, to our knowledge, the first publicly released labels specifically on shoulder radiograph acquisition quality. Labeling focused on Grashey (True AP) and axillary views, the most frequently repeated shoulder radiograph views in clinical practice. Each radiograph was categorized as diagnostically adequate or requiring repeat imaging. Using these labeled images, we developed SQUIRE (SHoulder QUality Image REviewer), a real-time heterogeneous ensemble model composed of lightweight (< 50M parameters) architectures selected through intra- and inter-architectural five-fold cross-validation. Internally, SQUIRE achieved an average F1 score of 0.943 and accuracy of 0.941, outperforming individual architectures and demonstrating reduced variability across folds. External validation on a temporally and institutionally distinct dataset revealed expected performance degradation due to domain and annotation shift. Nevertheless, SQUIRE maintained robust discrimination capacity in zero-shot settings (ROC AUC = 0.82) and few-shot adaptation (ROC AUC = 0.85). Comparison with a frozen medical foundation model further highlighted the advantage of domain-specialized, lightweight architectures for acquisition-quality assessment. By openly releasing these annotations and code, we establish a reproducible benchmark for low-latency, point-of-care radiographic quality assessment.
Ähnliche Arbeiten
Refinement and reassessment of the SERVQUAL scale.
1991 · 3.967 Zit.
Features and uses of high-fidelity medical simulations that lead to effective learning: a BEME systematic review
2005 · 3.784 Zit.
Radiobiology for the Radiologist.
1974 · 3.502 Zit.
International evidence-based recommendations for point-of-care lung ultrasound
2012 · 2.818 Zit.
Radiation Dose Associated With Common Computed Tomography Examinations and the Associated Lifetime Attributable Risk of Cancer
2009 · 2.431 Zit.